Tools Required
J 39400-A Halogen Leak
Detector
Removal Procedure
- Recover the refrigerant from the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Remove the evaporator outlet hose retaining
nut (5) from the accumulator.
- Remove the compressor inlet hose retaining nut (2).
- Disconnect the low pressure sensor electrical connector.
- Remove the retaining nuts (3) from the accumulator retaining bracket.
- Remove the accumulator (5) from the bracket.
- Remove the sealing washers.
Installation Procedure
- Add oil to the accumulator. Refer to
Refrigerant System Capacities
.
- Install the accumulator (5) to the bracket.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the nuts (3) to the accumulator retaining bracket.
Tighten
Tighten the nuts to 9 N·m (80 lb in).
- Connect the low pressure sensor electrical connector.
- Install new sealing washers. Refer to
O-Ring Replacement
.
- Install the evaporator outlet hose.
- Install the evaporator outlet hose retaining nut (5) to the accumulator.
Tighten
Tighten the nut to 16 N·m (12 lb ft).
- Install the compressor inlet hose.
- Install the compressor inlet hose retaining nut (2) to the accumulator.
Tighten
Tighten the nut to 16 N·m (12 lb ft).
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fittings of the component using the J 39400-A
.