Auxiliary Generator Replacement for Chevrolet Kodiak C-Series (Conventional) C6/C7/C8 2008
Removal Procedure
Caution: Refer to Battery Disconnect Caution in the Preface section.
- Disconnect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
.
- Remove the air cleaner. Refer to
Air Cleaner Assembly Replacement
for the 6.6L (LMM) .
- Remove the drive belt. Refer to
Drive Belt Replacement
.
- Disconnect the engine wiring harness electrical connector (1) from the generator.
- Reposition the engine wiring harness boot (8).
- Remove the generator terminal nut (9).
- Remove the engine wring harness terminal (10) from the generator.
- Remove the auxiliary generator bolts (3).
- Remove the auxiliary generator (2).
Installation Procedure
- Install the auxiliary generator (2).
Notice: Refer to Fastener Notice in the Preface section.
- Install the auxiliary generator bolts (3).
Tighten
Tighten the bolts to 50 N·m (37 lb ft).
- Install the engine wring harness terminal (10) to the generator.
- Install the generator terminal nut (9).
Tighten
Tighten the nut to 25 N·m (18 lb ft).
- Position the engine wiring harness boot (8).
- Connect the engine wiring harness electrical connector (1) to the generator.
- Install the drive belt. Refer to
Drive Belt Replacement
.
- Install the air cleaner. Refer to
Air Cleaner Assembly Replacement
for the 6.6L (LMM) .
- Connect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
.