Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Instrument Cluster Schematics Connector End View Reference: Instrument Panel, Gages, and Console Connector End Views | |||
1 | Did you perform the Instrument Cluster Diagnostic System Check? | Go to Step 2 | |
2 |
Does the IPC perform the displays test? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 7 |
4 | Connect a test lamp between the ignition 1 voltage circuit of the IPC and the ground circuit of the IPC. Does the test lamp illuminate? | Go to Step 5 | Go to Step 6 |
5 | Inspect for poor connections at the harness connector of the IPC. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 9 | Go to Step 8 |
6 | Repair the open or the high resistance in the IPC ground circuit. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 9 | -- |
7 | Repair the open, the short to ground or the high resistance in the ignition 1 voltage circuit. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 9 | -- |
8 |
Important: Program the replacement IPC Replace the IPC. Refer to Instrument Cluster Replacement .Did you complete the replacement? | Go to Step 9 | -- |
9 | Operate the system in order to verify the repair. Did you find and correct the condition? | System OK | Go to Step 3 |