Step
| Action
| Value(s)
| Yes
| No
|
1
|
- Disconnect the blower motor resistor.
- Place the ignition switch in the RUN position.
- Place the heater - A/C control in the VENT position.
- Place the blower switch in the OFF position.
- Use a test lamp to backprobe between the following blower motor
resistor harness connector terminals and ground:
Does the test lamp light?
| --
|
Go to Step 2
|
Go to Step 5
|
2
|
- Keep the probe connected to the same terminal that turned the
test light on.
- Disconnect the heater - A/C control connector C 1.
Did the test lamp light?
| --
|
Go to Step 3
|
Go to Step 4
|
3
| Locate and repair a short to B+ in the affected circuit:
• | LO - Blower motor resistors harness connector terminal D
circuit 60 (YEL). |
• | M1 - Blower motor resistors harness connector terminal B
circuit 63 (TAN). |
• | M2 - Blower motor resistors harness connector terminal A
circuit 72 (LT BLU). |
Is the repair complete?
| --
| Go to
HVAC Blower Controls System Check
| --
|
4
| Replace
the heater - A/C control. Refer to
Control Assembly Replacement
.
Is the repair complete?
| --
| Go to
HVAC Blower Controls System Check
| --
|
5
|
- Place the ignition switch in the OFF position.
- Disconnect the blower motor relay.
- Place the ignition switch in the ON position.
- Use a test lamp to backprobe between the blower motor relay harness
connector terminal C 2 circuit 52 (ORN) and ground.
Does the test lamp light?
| --
|
Go to Step 6
|
Go to Step 8
|
6
|
- Place the ignition switch in the OFF position.
- Disconnect the heater - A/C control connector C 1.
- Place the ignition switch in the ON position.
- Use a test lamp to backprobe between blower motor relay harness
connector terminal C 2 and ground.
Does the test lamp light?
| --
|
Go to Step 4
|
Go to Step 7
|
7
| Locate and repair the short to B+ in circuit 52(ORN).
Is the repair complete?
| --
| Go to
HVAC Blower Controls System Check
| --
|
8
|
- Place the ignition switch in the OFF position.
- Connect the blower motor resistor connector.
- Place the ignition switch in the ON position.
- Use a test lamp to probe between the blower motor relay harness
connector terminal B 2 and ground.
Does the test lamp light?
| --
|
Go to Step 9
|
Go to Step 12
|
9
|
- Turn the ignition switch to the OFF position.
- Disconnect the blower motor resistor.
- Turn the ignition switch to the ON position.
- Use a test lamp to backprobe between the blower motor relay harness
connector terminal B 2 and ground.
Does the test lamp light?
| --
|
Go to Step 10
|
Go to Step 11
|
10
| Locate and repair the short to B+ in circuit 101 (DK BLU).
Is the repair complete?
| --
| Go to
HVAC Blower Controls System Check
| --
|
11
| Replace
the blower motor resistor. Refer to
Blower Motor Resistor Replacement
.
Is the repair complete?
| --
| Go to
HVAC Blower Controls System Check
| --
|
12
| Use
a test lamp to backprobe between the blower motor relay harness connector
terminal C 1 and ground.
Does the test lamp light?
| --
|
Go to Step 13
|
Go to Step 14
|
13
| Locate and repair a short to B+ in CKT 65 (PPL).
Is the repair complete?
| --
| Go to
HVAC Blower Controls System Check
| --
|
14
| Replace
the blower motor relay.
Is the repair complete?
| --
| Go to
HVAC Blower Controls System Check
| --
|