Important: Before attempting the Fuel Tank Leak Check place a dry chemical (Class
B) fire extinguisher near the work area.
- Install the J 41415-40
Fill Tank Cap Adaptor.
- Connect the J 41413
EVAP Pressure/Purge Diagnostic Station to the fill tank cap adaptor.
- With a scan tool, seal the EVAP system.
- Raise the vehicle on a hoist. Refer to
Vehicle Lifting Caution
in Cautions and Notices.
- With the EVAP diagnostic station, maintain 15 in. H2O (3.75 kPa)
within the fuel tank.
Important: It may be necessary to partially lower the fuel tank to inspect the
top of the fuel tank and fuel sender assembly O-ring. Refer to
Fuel Tank Replacement
.
- With the J 41416
Ultrasonic Leak Detector, test for leaks in the fuel tank and EVAP pipes.
- Visually inspect for fuel leaking from the fuel tank.
- If a leak is detected refer to the following component replacements: