Removal Procedure
- Disconnect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
in
Engine Electrical.
- Remove the right side instrument panel insulator. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel, Gauges and Console.
- Disconnect the blower motor electrical connector.
- Remove the blower motor
mounting bolts.
- Remove the blower motor.
Installation Procedure
- Install the blower motor.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the blower
motor mounting bolts.
Tighten
Tighten the blower motor bolts to 20 N·m (14 lb in).
- Connect the blower motor electrical connector.
- Install the right side instrument panel insulator. Refer to
Instrument Panel Insulator Replacement
in
Instrument Panel, Gauges and Console.
- Connect the negative battery ground cable. Refer to
Battery Negative Cable Disconnection and Connection
in
Engine Electrical.