Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | Go to Diagnostic System Check |
2 | Inspect the HVAC fuse in the fuse block. Is the HVAC fuse open? | -- | Go to Step 3 | Go to Step 4 |
3 | Locate and repair a short to ground in circuit 41 (BRN). Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 9 | -- |
4 |
Does the test lamp light? | -- | Go to Step 6 | Go to Step 5 |
5 | Locate and repair a poor connection or an open in circuit 1236 (WHT/BLK). Refer to Testing for Intermittent Conditions and Poor Connections and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 9 | -- |
6 | Use a test lamp connected to B+ to probe the Temperature Actuator connector terminal 7 Does the test lamp light? | Go to Step 8 | Go to Step 7 | |
7 | Repair the fault in circuit 150 (BLK). Refer to Testing for Intermittent Conditions and Poor Connections and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 9 | -- |
8 | A fault has occurred in the vacuum selector, vacuum source, vacuum actuators, vacuum hoses to actuators, linkage from actuators to values, or faulty valves. Refer to Vacuum System for further diagnosis. Is the action complete? | -- | Go to Step 9 | -- |
9 | Verify that the system operates properly . Does the system operate properly ? | -- | System OK | Go to Symptoms |