Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | Go to Diagnostic System Check |
2 | Inspect the HVAC fuse in the fuse block. Is the HVAC fuse open? | -- | Go to Step 3 | Go to Step 4 |
3 | Locate and repair a short to ground in circuit 41 (BRN). Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 6 | -- |
4 | A fault has occurred in the vacuum selector, vacuum source, vacuum actuators, vacuum hoses to actuators, linkage from actuators to values, or faulty valves. Refer to Vacuum System for further diagnosis. Is the action complete? | -- | Go to Step 6 | Go to Step 5 |
5 | Replace the heater-A/C control. Refer to Control Assembly Replacement . Is the repair complete? | -- | Go to Step 6 | -- |
6 | Verify that the system operates properly . Does the system operate properly ? | -- | System OK | Go to Symptoms |