Step | Action | Yes | No |
---|---|---|---|
1 | Inspect fuse 23. Is the fuse open? | Go to Step 8 | Go to Step 2 |
2 | Using a test lamp, backprobe between the stop lamp switch harness connector C1 between terminal A and ground. Does the test lamp illuminate? | Go to Step 3 | Go to Step 6 |
3 |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 5 |
4 | Repair the poor connection or an open in circuit 17 between the stop lamp switch and S205. Is the repair complete? | -- | |
5 | Adjust or replace the stop lamp switch. Refer to Stop Lamp Switch Adjustment in Hydraulic Brakes. Is the repair complete? | -- | |
6 | Repair the poor connection or an open in circuit 140. Is the repair complete? | -- | |
7 | Repair a short to ground in circuit 140. Is the repair complete? | -- | |
8 | Check circuit 140 for a short to ground. Is there a short to ground in circuit 140? | Go to Step 7 | Go to Step 9 |
9 | Repair a short to ground in circuit 17. Is the repair complete? | -- |