Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Door Locks System Check performed? | -- | Go to Step 2 | Go to Power Door Locks System Check in Doors |
2 |
Refer to Transmitter Programming . Does the UNLOCK function work on all of the doors after performing the transmitter programming procedure? | -- | System OK | Go to Step 3 |
3 |
Is the resistance less than the specified value? | 2 ohms | Go to Step 4 | Go to Step 5 |
4 | Replace the RCDLR. Refer to Receiver Replacement . Is the repair complete? | -- | System OK | -- |
5 | Repair the following conditions in CKT 194 between the RCDLR and S312:
Is the repair complete? | -- | System OK | -- |