• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Inside Air Temperature Sensor Signal | B0168 03 | B0168 07 | B0168 07 | 1 |
Ambient Air Temperature Sensor Signal | B0158 03 | B0158 07 | B0158 07 | 1 |
Low Reference | -- | B0158 07, B0168 07, B3933 07 | B0158 07, B0168 07, B3933 07 | 1 |
Left Sunload Sensor Signal | B0183 03 | B0183 07 | B0183 07 | 1 |
Right Sunload Sensor Signal | B0188 03 | B0188 07 | B0188 05 | 1 |
1. Air Temperature Malfunction |
The air temperature sensors are a 2-wire negative temperature co-efficient thermistor. The vehicle uses the following air temperature sensors:
• | Ambient Air Temperature Sensor |
• | Inside Air Temperature Sensor Assembly |
• | Upper Left Air Temperature Sensor |
• | Upper Right Air Temperature Sensor |
• | Lower Left Air Temperature Sensor |
• | Lower Right Air Temperature Sensor |
• | A/C Evaporator Temperature Sensor |
A signal and low reference circuit enables the sensor to operate. As the air temperature surrounding the sensor increases, the sensor resistance decreases. The sensor signal voltage decreases as the resistance decreases. The sensor operates within a temperature range between -40 to +101°C (-40 to +215°F). The sensor signal varies between 0-5 volts. The input of the duct air temperature sensors are different from the ambient and inside air temperature sensors. The HVAC control module converts the signal to a range between 0-255 counts. As the air temperature increases the count value will decrease. If the HVAC control module or auxiliary HVAC control module detects a malfunctioning sensor, then the control module software will use a defaulted air temperature value. The default value for the ambient and inside air temperature sensors will be displayed on the scan tool. The default value for the duct air temperature sensors will not be displayed on the scan tool. The scan tool parameter for the duct air temperature sensors are the actual state of the signal circuit. The default action ensures that the HVAC system can adjust the inside air temperature near the desired temperature until the condition is corrected.
The sunload sensor is a 2-wire photo diode. The vehicle uses left and right sunload sensors. The 2 sensors are integrated into the sunload sensor assembly. Low reference and signal circuits enable the sensor to operate. As the light shining upon the sensor gets brighter, the sensor resistance increases. The sensor signal decreases as the resistance increases. The sensor operates within an intensity range between completely dark and bright. The sensor signal varies between 0-5 volts. The HVAC control module converts the signal to a range between 0-255 counts. The sunload sensor provides the HVAC control module a measurement of the amount of light shining on the vehicle. Bright, or high intensity, light causes the vehicles inside temperature to increase. The HVAC system compensates for the increased temperature by diverting additional cool air into the vehicle. If the HVAC control module detects a malfunctioning sensor, then the control module software will use a defaulted sunload value. This value will not be displayed on the scan tool. The default action ensures that the HVAC system can adjust the inside air temperature near the desired temperature until the condition is fixed. The scan tool parameter for the sunload sensor is the actual state of the signal circuit.
Condition | Display |
---|---|
Using Scan Tool Special Function | Updates temperature display instantly |
When the A/C and Recirc buttons are pressed simultaneously. | Updates temperature display instantly |
At start up with the engine off less than 2 hours | Displays last stored temperature unless temperature has decreased. The outside air temperature reading is always instantly updated if ambient air temperature has decreased. |
At start up with the engine off more than 2 hours | Displays actual outside temperature |
Vehicle speed above 32 km/h (20 mph) for a minimum of 80 seconds | Updates temperature display at a filtered rate |
Vehicle speed above 72 km/h (45 mph) | Displays actual outside temperature |
Sensor ambient temperature reading is less than the last displayed value | Displays actual outside temperature |
When the ambient air decreases | Updates temperature display rapidly |
Control Module References for scan tool information
⇒ | If not within the specified range, refer to Sun Load Sensor Circuit Malfunction. |
⇒ | If not within the specified range, refer to Sun Load Sensor Circuit Malfunction. |
⇒ | If not within the specified range, refer to Ambient / Inside Air Temperature Sensor Circuit Malfunction. |
⇒ | If not within the specified range, refer to Inside Air Temperature Sensor Circuit Malfunction. |
⇒ | If not within the specified range, refer to Ambient / Evaporator Temperature Sensor Circuit Malfunction. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If less than the specified range test the appropriate signal circuit terminal A or B for a short to ground. If the circuit tests normal, replace the HVAC control module. |
⇒ | If greater than the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
⇒ | If less than the specified range, test the signal circuit terminal A for a short to ground. If the circuit tests normal, replace the HVAC control module. |
⇒ | If greater than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
⇒ | If less than the specified range, test the signal circuit terminal B for a short to ground. If the circuit tests normal, replace the HVAC control module. |
⇒ | If greater than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
⇒ | If not within the specified range, replace the appropriate sensor. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for HVAC control module replacement, programming and setup. |