Digital Multimeter.
Perform the following procedures while wiggling the harness from side to side. Continue this at convenient points (about 6 inches apart) while watching the test equipment.
• | Testing for Short to Ground in Wiring Systems. |
• | Testing for Continuity in Wiring Systems. |
• | Testing for a Short to Voltage in Wiring Systems. |
If the fault is not identified, perform the procedure below using the MIN MAX feature on the Digital Multimeter. This feature allows you to manipulate the circuit without having to watch the Digital Multimeter. The Digital Multimeter will generate an audible tone when a change is detected.
Important: The Digital Multimeter must be used in order to perform the following procedure since it can monitor current, resistance or voltage while recording the minimum (MIN), and maximum (MAX) values measured.
Important: The 100 ms RECORD mode is the length of time an input must stay at a new value in order to record the full change.
• | If the variation between the recorded MIN and MAX voltage values is 1 volt or greater an intermittent open or high resistance condition exists. Repair the condition as necessary. |
• | If the variation between the recorded MIN and MAX voltage values is less than 1 volt an intermittent open or high resistance condition does not exist. |