Removal Procedure
- Disconnect the electrical
connector from the fluid level sensor (4).
- Remove the fluid level
sensor (3). Use needle nose pliers in order to compress the sensor locking
tabs at the inboard side of the master cylinder reservoir.
Installation Procedure
- Install the fluid level
sensor (3) into the master cylinder reservoir (1) until the locking tabs snap
in place.
- Install the electrical