GM Service Manual Online
For 1990-2009 cars only

Step

Action

Value(s)

Yes

No

Important: A short to ground will cause an open fuse(s). Before performing this diagnostic procedure, inspect the fuse(s) for an open.

1

  1. Disconnect the hazard switch connector.
  2. Connect a test lamp between terminal B of the hazard switch connector and ground.

Does the test lamp light?

--

Go to Step 2

Go to Step 3

2

Connect a test lamp between terminal B and terminal A of the hazard switch connector.

Does the test lamp light?

--

Go to Step 4

Go to S tep 5

3

Backprobe the left IP wiring harness junction block connector C1 with a test lamp between terminal C12 and ground.

Does the test lamp light?

--

Go to Step 6

Go to Step 7

4

Replace the hazard switch. Refer to Hazard Flasher Switch Replacement in Instrument Panel, Gauges and Console.

Is the repair complete?

--

Go to Exterior Lights System Check

--

5

Repair the open in CKT 150 between the hazard switch and ground splice pack G201. Refer to Wiring Repairs

Is the repair complete?

--

Go to Exterior Lights System Check

--

6

Repair the open in CKT 1140 between the hazard switch and the left IP wiring harness junction block. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to Exterior Lights System Check

--

7

Replace the left IP wiring harness junction block. Refer to Relay/Fuse Center Replacement in Wiring Systems.

Is the repair complete?

--

Go to Exterior Lights System Check

--

Step

Action

Value(s)

Yes

No

Important: A short to ground will cause an open fuse(s). Before performing this diagnostic procedure, inspect the fuse(s) for an open.

1

  1. Backprobe the hazard switch connector with a test lamp between terminal G (inoperative RH lamps) or terminal F (inoperative LH lamps) and ground.
  2. Turn the ignition switch to the RUN position.
  3. Turn the inoperative turn signal ON.

Does the test lamp flash?

--

Go to Step 2

Go to Step 3

2

Replace the hazard switch. Refer to Hazard Warning Switch in Instrument Panel, Gauges and Console.

Is the repair complete?

--

Go to Exterior Lights System Check

--

3

Repair the open in CKT 15 or CKT 14 between the hazard switch and the respective (right or left) IP wiring harness junction block. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--

Go to Exterior Lights System Check

--