Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Important: A short to ground will cause an open fuse(s). Before performing this diagnostic procedure, inspect the fuse(s) for an open. | ||||
1 | Was the Body Control Module (BCM) System Check performed? | -- | ||
2 |
Is the VSS Signal reading active? | -- | Go to Engine Controls | |
3 | Inspect for a poor connection in CKT 817 at terminal A8 of the instrument cluster connector. Is a poor connection evident? | -- | ||
4 | Repair the poor connection in CKT 817 at terminal A8 of the instrument cluster connector. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
5 | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Is the repair complete? | -- | -- |