Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Was the Instrument Cluster Diagnostic System Check performed? | -- | ||||||
2 |
Did the fasten belts chime stop? | -- | ||||||
3 | Replace the seat belt switch. Refer to Seat Belt Side Buckle Replacement - Driver in Seat Belts. Is the repair complete? | -- | -- | |||||
4 |
Did the fasten belts chime stop? | -- | ||||||
5 | Repair the short to ground in CKT 238 between terminal A of the seat belt switch connector and terminal B12 of right IP wiring harness junction block connector C3. Is the repair complete? | -- | -- | |||||
6 |
Did the fasten belts chime stop? | -- | ||||||
7 | Replace the right IP wiring harness junction block. Refer to Relay/Fuse Center Replacement in Wiring Systems. Is the repair complete? | -- | -- | |||||
8 |
Did the fasten belts chime stop? | -- | ||||||
9 | Replace the SDM. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement in SIR. Is the repair complete? | -- | -- | |||||
10 |
Does the resistance measure within the specified range? | Infinite | ||||||
11 | Replace the BCM. Refer to the following procedures:
Did you complete the repair? | -- | -- | |||||
12 | Repair the short to ground in CKT 238 between terminal B1 of the right IP wiring harness junction block connector C2 and terminal 8 of the SDM connector. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- |