Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Important: A short to ground will cause an open fuse(s). Before performing this diagnostic procedure, Inspect the fuse(s) for a open. | ||||
1 |
Do the interior lamps light? | -- | ||
2 | Replace the remote control door lock receiver. Refer to Receiver Replacement . Is the repair complete? | -- | System OK | -- |
3 | Repair the open in CKT 1040 between the remote control door lock receiver and the left IP wiring harness junction block. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | System OK | -- |