Instrument Cluster Replacement for Chevrolet Malibu 2000
Removal Procedure
- Disable the SIR system. Refer to
Disabling the SIR System
in SIR.
- Remove the cluster trim plate. Refer to
Instrument Cluster Trim Panel Replacement
.
- Remove the screws attaching
the cluster (2).
- Pull the cluster (2) rearward in order to remove the cluster.
- Disconnect the electrical connector.
Installation Procedure
- Connect the electrical
connector.
- Install the cluster (2) to the instrument panel (1).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the IP
cluster attaching screws.
Tighten
Tighten the IP cluster to 2 N·m (18 lb in).
- Install the cluster trim plate. Refer to
Instrument Cluster Trim Panel Replacement
- Enable the SIR system. Refer to
Enabling the SIR System
in SIR.