Removal Procedure
- Remove the instrument
panel (IP) compartment from the IP carrier. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages and Console.
- Disconnect the electrical connector from the IP compartment lamp
switch.
- Use a small flat-bladed tool in order to release the retainers
on the IP compartment lamp switch.
- Remove the IP compartment lamp switch from the IP compartment.
- Remove the bulb from the lamp switch socket, if required.
Installation Procedure
- Install the bulb into
the IP compartment lamp switch socket, if required.
- Connect the electrical connector to the IP compartment lamp switch.
- Install the IP compartment lamp switch to the IP compartment.
- Press the switch into the IP compartment until the retainers are
fully seated.
- Install the IP compartment to the IP carrier. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel,
Gages and Console.