Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Wiper/Washer Schematics Connector End View Reference: Wiper/Washer Connector End Views DEFINITION: The low washer fluid indicator is always on or does not turn on with low washer fluid. | |||
1 | Did you perform the Wiper/Washers Diagnostic System Check? | Go to Step 2 | |
2 | Verify the fault is present. Does the system operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the low washer fluid indicator remain illuminated with the ignition ON? | Go to Step 6 | Go to Step 4 |
4 |
Does the low washer fluid indicator remain illuminated with the ignition ON? | Go to Step 5 | Go to Step 8 |
5 |
Does the low washer fluid indicator remain illuminated with the ignition ON? | Go to Step 11 | Go to Step 10 |
6 |
With the washer fluid level switch disconnected is the Washer Fluid Level status OK? | Go to Step 15 | Go to Step 7 |
7 | Test the washer fluid level switch signal circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 18 | Go to Step 16 |
8 |
With the washer fluid level switch signal circuit shorted to ground is the Low Washer Lamp status On? | Go to Step 13 | Go to Step 9 |
9 | Test the washer fluid level switch signal circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 18 | Go to Step 16 |
10 | Repair the washer fluid level switch ground circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Step 18 | -- |
11 | Inspect for poor connections at the washer fluid level switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 18 | Go to Step 12 |
12 | Replace the washer fluid level switch. Is the repair complete? | Go to Step 18 | -- |
13 | Inspect for poor connections at the instrument panel cluster. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 18 | Go to Step 14 |
14 | Inspect the low washer fluid indicator bulb for an open. Refer to Instrument Cluster Bulb Replacement in Lighting Systems. Did you find and correct the condition? | Go to Step 18 | Go to Step 15 |
15 | Replace the instrument panel cluster. Refer to Instrument Cluster Replacement in Instrument Panel, Gages, and Console. Is the repair complete? | Go to Step 18 | -- |
16 | Inspect for poor connections at the body control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 18 | Go to Step 17 |
17 | Replace the body control module. Refer to Body Control Module Replacement and Body Control Module (BCM) Programming/RPO Configuration in Body Control System. Is the repair complete? | Go to Step 18 | -- |
18 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |