The ambient light sensor indicates the light level to control the automatic headlamps and park lamps. The body control module (BCM) provides a 5 volt reference signal to the ambient light sensor through the ambient light sensor signal reference circuit. The BCM receives the modified voltage from the ambient light sensor through the ambient light sensor signal return circuit. A low voltage, under 1.5 volts signals a dark condition to the BCM and vice versa.
The ignition switch is in the ON position.
Any of the following conditions will set this DTC:
• | The ambient light sensor signal reference circuit is open for 5 seconds. |
• | The ambient light sensor signal reference circuit is shorted to ground for 5 seconds. |
• | The ambient light sensor signal return circuit is open for 5 seconds. |
• | The ambient light sensor signal return circuit is shorted to ground for 5 seconds. |
The headlamps and park lamps are always on with the ignition on.
• | The conditions for setting the DTC are no longer present. |
• | A history DTC clears after 100 malfunction free ignition cycles. |
• | The BCM receives the clear code command from the scan tool. |
If the DTC is a history DTC, the problem may be intermittent. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
The numbers below refer to the step numbers on the diagnostic table.
The normal operating voltage of the ambient light sensor (photocell) is 0.5-4.5 volts.
If the value is above 0.5 volts, with the sensor disconnected, a short to voltage exists. If the value is below 0.5 volts, a short to ground exists.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Schematic Reference: Headlights/Daytime Running Lights (DRL) Schematics | ||||
1 | Did you perform the Lighting System Diagnostic System Check? | -- | Go to Step 2 | |
Does the scan tool indicate that the PHOTOCELL VOLTAGE parameter is within the specified range? | 0.5-4.5 V | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 | |
Does the scan tool indicate that the PHOTOCELL VOLTAGE data parameter is greater than the specified value? | 0.5 V | Go to Step 5 | Go to Step 4 | |
4 | Test the signal circuit and the ground circuit of the ambient light sensor for a short to ground or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 10 | Go to Step 6 |
5 | Test the signal circuit and the ground circuit of the ambient light sensor for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 10 | Go to Step 7 |
6 | Inspect for poor connections at the harness connector of the ambient light sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 10 | Go to Step 8 |
7 | Inspect for poor connections at the harness connector of the body control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 10 | Go to Step 9 |
8 | Replace the ambient light sensor. Did you complete the replacement? | -- | Go to Step 10 | -- |
9 |
Important: Perform the set up procedure for the body control module. Replace the body control module. Refer to Body Control Module Replacement . Did you complete the replacement? | -- | Go to Step 10 | -- |
10 |
Does the DTC reset? | -- | Go to Step 2 | System OK |