The air delivery controls are divided into 4 areas:
• | HVAC Control Components |
• | Air Speed |
• | Air Distribution |
• | Recirculation Operation |
The HVAC control module is a non-GMLAN device that interfaces between the operator and the HVAC system to maintain air temperature and distribution settings. The battery positive and ignition 3 voltage circuits provide power to the control module. The HVAC control module during defrost mode will change the a/c compressor LED status from on to off. The control head displays recirc, outside air, a/c and rear defrost feedback status through LED indicators. The HVAC control head will display NO COMMUNICATION when checking DTCs or doing a vehicle diagnostic system check refer to Diagnostic Trouble Code (DTC) List - Vehicle and Diagnostic System Check - Vehicle . The control module supports the following features:
Feature | Availability |
---|---|
Afterblow | Dealer turn on feature |
Purge | Yes |
Personalization | No |
Actuator Calibration | Yes |
The mode or recirculation actuator is a 2 wire bi-directional electric motor. Two control circuits enable the actuator to operate. The control circuits use either a 0 or 12-volt value to co-ordinate the actuator movement. When the actuator is at rest, both control circuits have a value of 0 volts. In order to move the actuator, the HVAC control module grounds the appropriate control circuit for the commanded direction. The HVAC control module reverses the polarity of the control circuits to move the actuator in the opposite direction.
The HVAC control module determines the door position by counting motor pulses on one of the control circuits. These pulses are small voltage fluctuations that occur when the brush is shorted across 2 commutator contacts as the motor rotates. As the actuator shaft rotates, the HVAC control module monitors the voltage drop across an internal resistance to detect the pulses. The HVAC control module converts the pulses to counts with a range of 0 to 255 counts. The HVAC control module uses a range of 0-255 counts to index the actuator position.
The HVAC control module applies voltage to the blower motor control circuit that corresponds to the selected blower speed. The resistors and the blower motor are in a series circuit. The following list represents the number of resistors in series with the blower motor per particular speed request:
• | Low speed-4 resistors |
• | Medium 1 speed-3 resistors |
• | Medium 2 speed-2 resistors |
When the operator requests High speed, the HVAC control module applies voltage to the blower motor relay through the high blower motor control circuit. The voltage energizes the blower motor relay, connecting the blower motor to battery positive voltage.
The afterblow is a dealer turn on option. It is inactive in a new vehicle. The afterblow relay resides in the IBCM. The IBCM will directly turn on the hi blower fan relay to start the afterblow process.
The HVAC control module controls the mode actuator in order to distribute airflow to a desired outlet. When the mode switch is moved to the bi-level through defrost positions, the A/C compressor clutch engages and the recirculation actuator will be moved to the outside air position.
The film valve system has several operating characteristics:
• | The cycle time for a mode change will vary based on the starting point of the film valve relative to the requested mode position. |
• | The maximum time to achieve a mode change occur when the film valve travels between vent and defrost. |
• | Mode change times may very slightly based on variations in system airflow, temperature and voltage. |
• | The amount of air rush noise heard when a mode change is requested that causes the film valve to move through three or more primary modes is dependent on blower speed. |
• | Recalibration will typically occur when the engine is OFF. The actuator noise heard during recalibration may be more noticeable than during normal operation. |
The HVAC control module controls the air intake through the recirculation actuator. Recirculation is not available when the mode is in bi-level through defrost. The operator must activate the blower for Recirculation operation. When recirculation is selected the A/C compressor will be engaged automatically.