The number below refers to the step number in the diagnostic table.
Step | Action | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor operates in at least one, but not all, speed positions. | |||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |||||||
2 |
Does the blower motor operate at the desired speed in each speed position? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 | ||||||
3 |
Does the test lamp illuminate in each speed position? | Go to Step 14 | Go to Step 4 | ||||||
4 | Does the test lamp illuminate in the maximum speed position? | Go to Step 9 | Go to Step 5 | ||||||
5 |
Does the test lamp illuminate? | Go to Step 6 | Go to Step 17 | ||||||
6 |
Does the test lamp illuminate? | Go to Step 8 | Go to Step 7 | ||||||
7 | Test the high blower motor control circuit of the blower motor relay for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 22 | Go to Step 16 | ||||||
8 | Test the ground circuit of the blower motor relay for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 22 | Go to Step 13 | ||||||
Does the test lamp illuminate in each speed position? | Go to Step 13 | Go to Step 10 | |||||||
10 | Test the blower motor supply voltage circuit between the blower motor resistor and blower motor relay for the following:
Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 22 | Go to Step 11 | ||||||
11 |
Important: Place the blower motor switch in the correct speed position for the control circuit that you are testing.
Does the test lamp illuminate in each speed position? | Go to Step 15 | Go to Step 12 | ||||||
12 | Test the applicable blower motor control circuit of the blower motor resistor for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 22 | Go to Step 16 | ||||||
13 | Inspect for poor connections at the harness connector of the blower motor relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 22 | Go to Step 18 | ||||||
14 | Inspect for poor connections at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 22 | Go to Step 19 | ||||||
15 | Inspect for poor connections at the harness connector of the blower motor resistor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 22 | Go to Step 20 | ||||||
16 | Inspect for poor connections at the harness connector of the HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 22 | Go to Step 21 | ||||||
17 | Repair the battery positive voltage circuit of the blower motor relay. Refer to Wiring Repairs . Did you complete the repair? | Go to Step 22 | -- | ||||||
18 | Replace the blower motor relay. Did you complete the replacement? | Go to Step 22 | -- | ||||||
19 | Replace the blower motor. Refer to Blower Motor Replacement . Did you complete the replacement? | Go to Step 22 | -- | ||||||
20 | Replace the blower motor resistor assembly. Refer to Blower Motor Resistor Replacement . Did you complete the replacement? | Go to Step 22 | -- | ||||||
21 | Replace the HVAC control assembly. Refer to HVAC Control Module Replacement . Did you complete the replacement? | Go to Step 22 | -- | ||||||
22 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |