GM Service Manual Online
For 1990-2009 cars only

Diagnostic Fault Information

Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.

Circuit/System Description

Ignition voltage is supplied to the malfunction indicator lamp (MIL). The engine control module (ECM) turns the MIL ON by grounding the MIL control circuit.

Reference Information

Schematic Reference

Engine Controls Schematics

Connector End View Reference

Engine Control Module Connector End Views

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Scan Tool Data List

Circuit/System Verification

The MIL should turn ON and OFF when commanded with a scan tool.

Circuit/System Testing

  1. Turn OFF the ignition.
  2. Disconnect the ECM.
  3. Turn ON the ignition with the engine OFF.
  4. If the MIL is still ON, test the MIL control circuit for a short to ground.
    If the MIL control circuit tested OK and the MIL stayed ON, replace the instrument panel cluster (IPC).
    If the MIL control circuit tested OK and the MIL went out when the ECM was disconnected, replace the ECM.
  5. Measure for 12 volts from the MIL ignition voltage circuit in the ECM harness connector to a ground.
  6. If there is less than 12 volts, test the MIL ignition voltage circuit for an open, or a short to ground and an open fuse.
  7. Remove the fuse that supplies voltage to the MIL.
  8. Measure for less than 1 volt from the MIL control circuit in the ECM harness connector to a good ground.
  9. If there is more than 1 volt, test the MIL control circuit for a short to voltage.
  10. Install the fuse that supplies voltage to the MIL.
  11. The MIL should illuminate with a 3-amp fused jumper wire connected between the MIL control circuit in the ECM harness connector and a good ground.
  12. If the MIL does not illuminate, test the MIL control circuit for an open or high resistance.
    If the MIL control circuit tests OK, replace the IPC.
    If the MIL does illuminate, but does not when commanded ON with a scan tool, replace the ECM.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Control Module References for ECM replacement, setup, and programming
    •  Instrument Cluster Replacement