• | The condition may be intermittent. Refer to Testing for Intermittent Conditions and Poor Connections . |
• | Inspect the air delivery system for the following conditions: |
- | An obstruction to the airflow |
- | Air leaks |
- | Misaligned air ducts |
- | Broken or binding linkages or doors |
The numbers below refer to the step numbers on the diagnostic table.
Step | Action | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air does not flow correctly from the air distribution outlets. | |||||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |||||||||||
2 |
Is the blower motor OFF? | Go to Step 3 | Go to Blower Motor Always On | ||||||||||
3 | Place the blower motor switch in each speed position. Does the blower motor operate in each speed position? | Go to Step 4 | Go to Blower Motor Inoperative | ||||||||||
4 | Does the blower motor operate at the desired speeds? | Go to Step 5 | Go to Blower Motor Malfunction | ||||||||||
5 | Place the mode switch in each mode position. Does the air flow from the correct air distribution outlets in each selected mode position? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 6 | ||||||||||
6 | Test the mode door control A circuit and the mode door control B circuit for the following:
Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 7 | ||||||||||
Does the actuator shaft rotate in both directions? | Go to Step 8 | Go to Step 9 | |||||||||||
8 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 12 | ||||||||||
9 | Inspect the mode door and actuator for the following conditions:
Did you find and correct the condition? | Go to Step 13 | Go to Step 10 | ||||||||||
10 | Inspect for poor connections at the harness connector of the mode actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 11 | ||||||||||
11 |
Important: Perform the recalibration procedure for the mode actuator after replacement. Replace the mode actuator. Refer to Mode Actuator Replacement . Did you complete the replacement? | Go to Step 13 | -- | ||||||||||
12 | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 13 | -- | ||||||||||
13 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |