Step | Action | Yes | No | ||||||||||||
DEFINITION: Noise originating from the HVAC module. | |||||||||||||||
1 | Were you sent here from Symptoms or another diagnostic table? | Go to Step 2 | Go to Symptoms - HVAC Systems - Manual or | ||||||||||||
2 | Important: A crinkle noise during mode valve recalibration is normal. Recalibration could occur when the ignition switch is OFF.
Is noise evident when selecting recirculation? | Go to Step 6 | Go to Step 3 | ||||||||||||
3 | Is noise evident when selecting temperature? | Go to Step 6 | Go to Step 4 | ||||||||||||
4 | Is noise evident when selecting mode ? | Go to Step 5 | Go to Step 2 | ||||||||||||
5 |
Is dust, dirt or debris present? | Go to Step 11 | Go to Step 12 | ||||||||||||
6 | Remove the HVAC module. Refer to HVAC Module Assembly Replacement . Is action complete? | Go to Step 7 | -- | ||||||||||||
7 |
Were any of these conditions found? | Go to Step 10 | Go to Step 8 | ||||||||||||
8 | Inspect air flow door for warping or cracking. Is air flow door in normal condition? | Go to Step 13 | Go to Step 9 | ||||||||||||
9 | Replace air flow door . Is repair complete? | Go to Step 13 | -- | ||||||||||||
10 | Remove any obstructions or foreign material found. Is action complete? | Go to Step 13 | -- | ||||||||||||
11 | Vacuum and remove dust, dirt and debris. Is action complete? | Go to Step 14 | -- | ||||||||||||
12 | Replace mode valve. Refer to Mode Valve Assembly Replacement . Is action complete? | Go to Step 14 | -- | ||||||||||||
13 | Install HVAC Module. Refer to HVAC Module Assembly Replacement . Is action complete? | Go to Step 14 | -- | ||||||||||||
14 | Operate the system to verify the repair. Did you find and correct the condition? | System OK | Go to Step 2 |