Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C Performance Table below? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK | Go to Symptoms - HVAC Systems - Manual or |
Ambient Temperature | Relative Humidity | Low Side Service Port Pressure | High Side Service Port Pressure | Maximum Left Center Discharge Air Temperature |
---|---|---|---|---|
13-18°C (55-65°F) | 0-100% | 175-200 kPa (25-30 psi) | 500-850 kPa (70-125 psi) | 5°C (40°F) |
19-24°C (66-75°F) | Less than 40% | 175-240 kPa (25-35 psi) | 690-1100 kP (100-160 psi) | 5°C (40°F) |
Greater than 40% | 175-240 kPa (25-35 psi) | 690-1100 kP (100-160 psi) | 7°C (45°F) | |
25-29°C (76-85°F) | Less than 35% | 175-240 kPa (25-35 psi) | 1000-1300 kPa (145-190 psi) | 10°C (50°F) |
35-60% | 175-240 kPa (25-35 psi) | 1000-1340 kPa (145-195 psi) | 10°C (50°F) | |
Greater than 60% | 175-280 kPa (25-40 psi) | 1000-1370 kPa (145-200 psi) | 10°C (50°F) | |
30-35°C (86-95°F) | Less than 30% | 175-280 kPa (25-40 psi) | 1240-1590 kPa (180-230 psi) | 13°C (55°F) |
30-50% | 175-280 kPa (25-40 psi) | 1240-1620 kPa (180-235 psi) | 13°C (55°F) | |
Greater than 50% | 175-280 kPa (25-40 psi) | 1240-1650 kPa (180-240 psi) | 13°C (55°F) | |
36-41°C (96-105°F) | Less than 20% | 240-320 kPa (35-45 psi) | 1500-1860 kPa (215-270 psi) | 15°C (60°F) |
20-40% | 240-320 kPa (35-45 psi) | 1500-1900 kPa (215-275 psi) | 15°C (60°F) | |
Greater than 40% | 240-320 kPa (35-45 psi) | 1500-1900 kPa (215-275 psi) | 15°C (60°F) | |
42-46°C (106-115°F) | Less than 20% | 280-350 kPa (40-50 psi) | 1765-2100 kPa (255-305 psi) | 18°C (65°F) |
Greater than 20% | 280-350 kPa (40-50 psi) | 1765-2100 kPa (255-305 psi) | 18°C (65°F) | |
47-49°C (116-120°F) | Below 30% | 320-380 kPa (45-55 psi) | 2000-2240 kPa (290-325 psi) | 20°C (70°F) |