Removal Procedure
- Remove the intake manifold cover. Refer to
Intake Manifold Cover Replacement
.
- disconnect the positive crankcase ventilation (PCV) fresh air tube quick connect fitting from the air cleaner outlet duct. Refer to
Plastic Collar Quick Connect Fitting Service
.
- Reposition the tube out of the way.
- Loosen the air cleaner outlet duct clamps (1, 2) at the mass air flow (MAF)/intake air temperature (IAT) sensor and throttle body.
- Remove the air cleaner outlet duct bolt (5).
- Remove the air cleaner outlet duct spacer (4) and insulator (5), if required.
- Remove the air cleaner outlet duct.
Installation Procedure
- Position and install the air cleaner outlet duct to the MAF/IAT sensor and the throttle body.
- Position the air cleaner outlet duct insulator (5) and spacer (4), if required.
Notice: Refer to Fastener Notice in the Preface section.
- Install the air cleaner outlet duct bolt (5).
Tighten
Tighten the bolt to 10 N·m (89 lb in).
- Tighten the air cleaner outlet duct clamps (1, 2) at the MAF/IAT sensor and throttle body.
Tighten
Tighten the clamp to 4 N·m (35 lb in).
- Position the PCV tube.
- Connect the PCV fresh air tube quick connect fitting to the air cleaner outlet duct. Refer to
Plastic Collar Quick Connect Fitting Service
- Install the intake manifold cover. Refer to
Intake Manifold Cover Replacement
.