Tools Required
J 38185
Hose Clamp Pliers
Removal Procedure
- Disconnect the hybrid battery. Refer to
Hybrid Battery Service Disconnect/Connect
.
- Drain the cooling system. Refer to
Cooling System Draining and Filling
.
- Remove the battery tray. Refer to
Battery Tray Replacement
.
- Reposition the power brake booster vacuum hose (2) clamp at the intake manifold.
- Remove the power brake booster vacuum hose from the intake manifold.
- Remove the power brake booster vacuum hose from the clamp (2) on the generator control module coolant outlet hose.
- Reposition the power brake booster vacuum hose out of the way.
Caution: To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the generator starter. After removing the 36V battery cables from the generator battery, remove both
engine wiring harness connectors from the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all 36V, 12V, and 3-phase connections, are less than 3 volts using
a DMM before proceeding.
- Remove the 2 connector position assurance (CPA) retainers (3).
- Disconnect the 2 engine wiring harness electrical connectors (2) from the generator control module.
- WAIT at least 5 minutes in order to allow the voltage stored in the generator control module to discharge.
- Remove the generator control module bracket reinforcement bolt (1) and nuts (2).
- Remove the generator control module bracket reinforcement (3).
- Reposition the generator control module coolant inlet hose clamp (1) at the generator control module
using the
J 38185
or equivalent.
- Remove the generator control module coolant inlet hose (2) from the generator control module.
- Reposition the generator control module coolant outlet hose clamp (1) at the generator control module
using the
J 38185
or equivalent.
- Remove the generator control module coolant outlet hose (2) from the generator control module.
- Loosen the generator control module cover integral bolts (1) and remove the cover (2).
- The generator control module will have to be checked for voltage potential using a voltmeter. First, verify that the voltmeter works:
18.1. | Set the voltmeter to DC voltage. |
18.2. | Measure the vehicle 12-volt battery voltage. |
18.3. | The meter should read greater than +12 volts DC. |
- Check the generator control module for voltage potential, in order to ensure that the module has been disabled.
19.1. | Measure from the 36-volt positive terminal (3) to a known good chassis ground. The voltage should be less than 3 volts. |
19.2. | Measure from the 12-volt positive terminal (2) to a known good chassis ground. The voltage should be less than 3 volts. |
19.3. | Measure from the ground terminal (4) to a known good chassis ground, checking for continuity. |
Caution: To help avoid personal injury, always treat the 3-phase cable and connectors as if voltage is present and as if the surface of all parts
of the cable is hot.
- Verify that the generator control module 3-phase cables are disabled.
20.1. | Measure from each phase 1, 2, and 3 connection (1) to a known good chassis ground. The voltage should be less than 3 volts. |
20.2. | After verifying that there is no voltage present, the generator control module 3-phase cables can now be removed from the generator control module. |
- Remove the 36-volt terminal block nuts (1) from the generator control module.
- Lift up, and reposition the 36-volt terminal block (2), secure the block out of the way. Discard the terminal block seal.
- Remove the generator control module 3-phase cable terminal block nuts (1) from the generator
control module.
- Lift up, and reposition the generator control module 3-phase cable terminal block (2), secure the block out of the way. Discard the terminal block seal.
- Disconnect the engine wiring harness electrical connector (1) from the
transaxle auxiliary pump module.
- Remove the generator control module ground strap nut (1) and strap (2) from the module stud.
- Remove the engine wiring harness clips (1) from the battery tray bracket
studs.
- Remove the generator control module nuts (1).
- Remove the generator control module (with bracket) (2) from the vehicle.
- Place the generator control module assembly on a clean work surface.
- Remove the generator control module bracket to module bolts (2). Separate the generator control module (1) from the bracket (3).
- If replacing the generator control module. remove the transaxle auxiliary pump control module. Refer to
Auxiliary Fluid Pump Control Module Replacement
.
Installation Procedure
- If the generator control module was replaced. install the transaxle auxiliary pump control module. Refer to
Auxiliary Fluid Pump Control Module Replacement
.
Notice: Refer to Fastener Notice in the Preface section.
- Position the generator control module (1) to the bracket (3), and install the generator control module bracket to module bolts (2).
Tighten
Tighten the bolts to 10 N·m (89 lb in).
- Install the generator control module (with bracket) (2) to the vehicle.
- Install the generator control module bracket nuts.
Tighten
Tighten the nuts to 10 N·m (89 lb in).
- Install the generator control module ground strap (2) to the stud and install the ground strap nut (1) to the module.
Tighten
Tighten the nut to 10 N·m (89 lb in).
- Connect the engine wiring harness electrical connector (1) to the transaxle
auxiliary pump.
- Place a NEW terminal block seal onto the generator control module.
- Install the generator control module 3-phase cable terminal block (2) onto the generator control module.
- Install the generator control module 3-phase cable terminal block nuts (1) until snug.
- Tighten the generator control module 3-phase cable terminal block nuts
in the sequence shown.
Tighten
Tighten the nuts to 8 N·m (71 lb in).
- Place a NEW terminal block seal onto the generator control module.
- Unsecure, and position the 36-volt terminal block (2) to the generator control module.
- Install the 36-volt terminal block nuts (1) to the generator control module.
Tighten
Tighten the nuts to 10 N·m (89 lb in).
- Place the generator control module cover (2) on top of the generator control module and tighten bolts (1).
Tighten
Tighten the bolts to 10 N·m (89 lb in).
- Install the generator control module coolant outlet hose (2) to the generator control module.
- Position the generator control module coolant outlet hose clamp (1) at the generator control module using the
J 38185
or equivalent.
- Install the generator control module coolant inlet hose (2) to the generator control module.
- Position the generator control module coolant inlet hose clamp (1) at the generator control module using the
J 38185
or equivalent.
- Install the generator control module bracket reinforcement (3).
- Install the generator control module bracket reinforcement bolt (1) and nuts (2).
Tighten
Tighten the bolt/nuts to 10 N·m (89 lb in).
- Connect the 2 engine wiring harness electrical connectors (2) to the generator
control module.
- Install the 2 CPA retainers (3).
- Position and install the power brake booster vacuum hose (2) to the intake manifold.
- Position the power brake booster vacuum hose clamp at the intake manifold.
- Install the power brake booster vacuum hose to the clamp (2) to the generator control module coolant outlet hose.
- Install the battery tray. Refer to
Battery Tray Replacement
.
- Fill the cooling system. Refer to
Cooling System Draining and Filling
.
- Connect the hybrid battery. Refer to
Hybrid Battery Service Disconnect/Connect
.
- If the generator control module was replaced, program the NEW module. Refer to
Control Module References
.
- Using a Tech 2, command an autostart in order to verify that the system is working properly.