• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The auxiliary power module (APM) temperature sensor is used for overheat protection. The thermistor is located on the control board, near the phase APM power MOSFET. The starter/generator control module (SGCM) monitors the APM temperature sensor for the following:
• | To detect if the internal APM temperature sensor is shorted low. |
• | To detect if the internal APM temperature sensor is shorted high. |
If one of the above conditions is detected, the SGCM will set the appropriate DTC.
The engine is running.
FET temperature sensor signal for APM is less than 0.2 volts for 1 second.
APM temperature sensor output voltage is greater than 4.6 volts (-14°C or 6.8°F) and APM temperature is greater than 55°C (131°F) for 1 second.
APM 50 percent maximum current output
Normal range for 10 seconds
Possible APM temperature sensor short to ground or open
Possible APM temperature sensor short to voltage
Starter/Generator Description and Operation
Control Module References for scan tool information
Caution: To help avoid personal injury, be careful when working in the vicinity of the generator battery disconnect control module. Internal components will still be live, 36V potential, even when the cover has been opened or removed.
⇒ | If the DTC resets, replace the SGCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for SGCM replacement, setup, and programming