• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The starter/generator control module (SGCM) monitors the phase U/V/W current sensor to detect 3 phase overcurrent and to protect the MOSFET.
• | Engine is running. |
• | Wake up signal is ON. |
Over current signal set for 20 ms.
• | Stop PWM (MGU shutdown) |
• | APM PWM OFF |
• | Battery disconnection (disconnect SW on/off) |
Over current signal not valid
• | Possible MGU winding short to other winding or short to case |
• | Possible FET breakdown or gate driver circuit fault |
Starter/Generator Description and Operation
Control Module References for scan tool information
⇒ | If any circuit indicates a short to ground , disconnect the 3-phase cables from the MGU. |
⇒ | If the short to ground condition is longer present, replace the MGU. |
⇒ | If any circuit does not test normal, replace the 3-phase cable assembly. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for SGCM replacement, setup, and programming |