• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The engine control module (ECM) performs a rationality check for the voltage sensor located internal to the battery energy control module (BECM) by comparing the pack power electronics bus, and module voltages. If the SGCM diagnostic causes the contactor open, this DTC could set falsely.
The engine is running.
• | Battery Pack Voltage - Pack Rationality Mean Voltage is greater than 2 volts. |
• | Pack Rationality Mean Voltage = (Power Electronics Voltage + ModVolt 1 + ModVolt 2 + ModVolt 3) / 2 |
Hybrid system is inactive.
Voltage difference between the battery pack and the average of the battery pack and the power electronics bus returns below the calibrated threshold.
If the SGCM diagnostic causes the contactor open, this DTC could set falsely.
Possible 36 volt cable open circuit between starter/generator control module (SGCM) and BECM.
Hybrid Energy Storage Schematics
Generator Battery Carrier Description and Operation
Control Module References for scan tool information
J 35616 GM Approved Terminal Test Kit
Caution: To help avoid personal injury, be careful when working in the vicinity of the generator battery disconnect control module. Internal components will still be live, 36V potential, even when the cover has been opened or removed.
Caution: To help avoid personal injury, be careful when working in the vicinity of the generator battery disconnect control module. Internal components will still be live, 36V potential, even when the cover has been opened or removed.
Important: In order to avoid damaging BECM X1 and X2 connector terminals, the proper test probes should be used. The proper test probes are as follows:
• | J-35616-65B for female terminals |
• | J-35616-64B for male terminals |
⇒ | If any measured voltages differ than 0.5 volt than the scanned voltage, test the voltage sensing harness for a short to ground or an open/high resistance. |
• | X1 terminal 12 and Generator Battery 3-X2 |
• | X1 terminal 2 and Generator Battery 2-X2 |
• | X1 terminal 11 and Generator Battery 1-X2 |
• | X1 terminal 1 and Generator Battery 1-X1 |
⇒ | If not within specified range, replace the voltage sensing harness assembly. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BECM replacement, setup, and programming |