• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category |
Circuit | Short to Ground | High Resistance | Open | Short to Voltage | Signal Performance |
---|---|---|---|---|---|
CMP Actuator Solenoid High Control | P0010 | P0010 | P0010 | P0010 | P0011 |
CMP Actuator Solenoid Low Reference | -- | P0010 | P0010 | -- | -- |
The camshaft position (CMP) actuator is attached to the camshaft and is hydraulically operated in order to change the angle of the camshaft relative to crankshaft position (CKP). The CMP actuator solenoid is controlled by the engine control module (ECM). The ECM sends a pulse width modulated 12-volt signal to a CMP actuator solenoid. The solenoid controls the amount of engine oil flow to the CMP actuator by extending a pintle within the solenoid. The pintle acts against a spool valve in the CMP actuator mechanism which is attached to the front of the camshaft. As the spool valve is moved, oil is directed to the CMP actuator, which rotates the camshaft. The CMP actuator can change the cam angle a maximum of 27 degrees.
• | The ignition is in Crank or Run. |
• | The system voltage is between 11-18 volts. |
• | DTC P0010 runs continuously when the above conditions are met. |
The ECM detects that the state of the driver and the state of the circuit do not match. The ECM will detect an open, short to ground, or a short to voltage on the high control circuit or an open on the low reference circuit for more than 6.25 seconds.
• | DTC P0010 is a Type B DTC. |
• | The CMP actuator is commanded to the home or parked position. |
DTC P0010 is a Type B DTC.
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
Important: The supply of clean pressurized engine oil to the CMP actuator is essential to CMP actuator performance.
Important: The engine will run rough and may require throttle input to keep running.
Important: You must complete the Circuit/System Verification before proceeding with Circuit/System Testing.
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. |
⇒ | If the test lamp illuminates, test the control circuit for short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If not the specified value, test the control circuit for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If not the specified value, test the control circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
Important: Ensure that the component is tested at 20°C (68°F).
⇒ | If the resistance is not within the specified range, replace the CMP actuator solenoid. |
Important: Do not allow the solenoid to be energized for more than 2 seconds.
⇒ | If the function does not perform as specified, replace the CMP actuator solenoid. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |