• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The starter/generator control module (SGCM) monitors the motor generator unit (MGU) temperature sensor for an overtemperature condition.
The engine is running.
MGU temperature is greater than 205°C (401°F) for 1 second.
Stop PWM (MGU shutdown)
MGU temperature is less than 150°C (212°F) for 3 seconds.
Possible MGU fan failure caused by obstructions, blockage to the vents or damaged fan.
Starter/Generator Description and Operation
Control Module References for scan tool information
⇒ | If the 3 phase cables are within torque specifications, replace the MGU. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Generator with Starter Replacement for MGU replacement.