    •  Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    •  Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptors

DTC P0AF8: Hybrid System Voltage

DTC P0AFB: Hybrid Battery System Voltage High

Circuit/System Description

P0AF8

The engine control module (ECM) monitors the correlation of the battery energy control module (BECM) battery voltage and the starter generator control module (SGCM) output voltage to detect a 36 volt cable open or fuse/relay failure.

P0AFB

The ECM also monitors to detect an over voltage condition and protect the MOSFET (load dump).

If either one of these conditions is detected, the appropriate DTC will set.

Conditions for Running the DTC

The engine is running.

Conditions for Setting the DTC

P0AF8

The 36 volt BECM battery voltage - 36 volt SGCM output voltage is greater than 5 volts for 4 seconds.

P0AFB

    • In the hardware, 36 volt over voltage signal from protection circuit (sets above 56 volts, clears below 53 volts) is set for 20 ms.
    • In the software, 36 volt output voltage is greater than 50 volts for 5 ms.

Action Taken When the DTC Sets

P0AF8, P0AFB

    • Stop PWM (MGU shutdown)
    • APM PWM off

Conditions for Clearing the DTC

P0AF8

36-volt voltage from BECM (42 VIN) is greater than 0 volt, main relay is closed, and 42 VIN invalid flag is ON.

P0AFB

    • In the hardware, clears 30 seconds after wakeup signal is ON.
    • In the software, voltage is normal for 100 ms and main relay is closed.

Diagnostic Aids

P0AF8

    • Possible 36 volt battery cable open
    • Possible Hybrid Battery Pack fuse open
    • Possible Hybrid Battery Pack contactor open
    • Possible Hybrid Battery Pack ground cable or connection

P0AFB

    • Possible 36 volt battery cable open (load dump)
    • Possible Hybrid Battery Pack fuse open
    • Possible Hybrid Battery Pack contactor open
    • Possible Hybrid Battery Pack ground cable or connection

Reference Information

Schematic Reference

    •  Hybrid Controls Schematics
    •  Hybrid Energy Storage Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Starter/Generator Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Verification

P0AF8

  1. If DTC is history, refer to Testing for Intermittent Conditions and Poor Connections.
  2. Ignition ON, observe the scan tool Hybrid Battery System Voltage parameter in the BECM data list and the Hybrid System Voltage parameter in the SGCM data list. The voltage should not differ by more than 5 volts.
  3. If greater than the specified value, continue with Circuit/System Testing.

P0AFB

  1. If DTC is history, refer to Testing for Intermittent Conditions and Poor Connections.
  2. Ignition ON, observe the scan tool Hybrid Battery System Voltage parameter in the BECM data list. The voltage should be less than 50 volts.
  3. If greater than the specified value , replace the SGCM.

Circuit/System Testing

P0AF8

  1. Verify the DTC is set as current.
  2. Ensure the hood is fully closed. Ignition ON, observe and record the scan tool Hybrid Battery System Voltage parameter in the SGCM data list.
  3. Open the hood. Gain access to the 36 volt output cable connection at the SGCM refer to Generator Control Module Cover Replacement
  4. Measure the voltage at the 36 volt output cable connection at the SGCM to ground, the voltage should not differ by more than 3 volts than the scan tool parameter recorded in step 2.
  5. If greater than the specified value replace the SGCM.
  6. Ignition ON, observe and record the scan tool Hybrid Battery System Voltage parameter in the BECM data list.
  7. Ignition OFF, remove the Hybrid Battery Pack service cover refer to Hybrid Battery Service Disconnect/Connect Inspect the 36  volt and ground cable connections of the Hybrid Battery Pack.
  8. Depress and hold the service disconnect for 20 seconds and measure the voltage at the Hybrid Battery Pack the 36  volt terminal to ground. The voltage should not differ by more than 3 volts from the voltage measured in step 4.
  9. If greater than the specified value, test the 36  volt cable for short to ground or an open/high resistance.
  10. Note some vehicles have a plastic cover over this area to be measured that must be removed. Measure the voltage at the Hybrid Battery Pack the 36  volt terminal pack side of contactor to ground. The voltage should not differ by more than 3 volts from the scan tool parameter display in step 5.
  11. If greater than specified value inspect the Hybrid Battery Pack ground cable for an open/high resistance or the Hybrid Battery Pack fuse for an open.
  12. If the ground circuit tests normal, the fuse was not open and voltage differs by more than 3 volts. Replace the BECM.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  36-Volt Battery Positive Cable Replacement
    •  Control Module References for BECM/SGCM replacement, setup, and programming.