Removal Procedure
- Remove the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement.
- Disconnect the engine wiring harness electrical connector (1) from the exhaust camshaft position (CMP) actuator solenoid valve (4), if required.
- Disconnect the engine wiring harness electrical connector (2) from the intake CMP actuator solenoid valve (3), if required.
- Remove the exhaust (1) CMP actuator solenoid valve bolt and valve, if required.
- Remove the intake (2) CMP actuator solenoid valve bolt and valve, if required.
- Inspect the solenoid valve O-ring seals for damage, replace as necessary.
Installation Procedure
- Lubricate the solenoid valve O-ring seals with clean engine oil.
Caution: Refer to Fastener Caution in the Preface section.
- Install the intake (2) CMP actuator solenoid valve and bolt, if required.
Tighten the bolt to
10 N·m (89 lb in).
- Install the exhaust (1) CMP actuator solenoid valve and bolt, if required.
Tighten the bolt to
10 N·m (89 lb in).
- Connect the engine wiring harness electrical connector (2) to the intake CMP actuator solenoid valve (3),
if required.
- Connect the engine wiring harness electrical connector (1) to the exhaust CMP actuator solenoid valve (4), if required.
- Install the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement.