| Table 1: | Starter/Generator Control Module Scan Tool Data Parameters | 
| Table 2: | Starter/Generator Control Module Scan Tool Output Controls | 
Parameter  | System State  | Expected Value  | Description  | 
|---|---|---|---|
Operating Conditions: Ignition ON  | |||
APM Control Mode  | --  | Off  | The scan tool displays Off, High to Low, Low to High or Not Used. This is the state of the auxiliary power module (APM) control mode.  | 
APM Control Status  | --  | Charging  | The scan tool displays Charging, Current Limited, Shutdown or Not Used. This is the auxiliary power module (APM) control status.  | 
Desired APM Voltage  | --  | Varies  | This displays Volts. This is the desired auxiliary power module (APM) voltage.  | 
Generator Starter Field Current  | --  | Varies  | This displays amps.  | 
Generator Starter Field Current  | --  | Enable  | The scan tool displays Enable or Disable. This is the current state of the generator starter field.  | 
Hill Hold Solenoid 1  | --  | Varies  | This displays %.  | 
Hill Hold Solenoid 2  | --  | Varies  | This displays %.  | 
Hill Hold Solenoid Relay  | --  | Varies  | This displays Enable or Disable. This is the current state of the hill hold solenoid relay.  | 
Hood Position  | --  | Closed  | The scan tool displays Open or Closed. This is the current position of the hood switch.  | 
Hybrid System Voltage  | --  | Varies  | This displays Volts. This is the current hybrid system voltage.  | 
SGCM 12 Volt Converter  | --  | Varies  | This displays amps.  | 
SGCM Converter Temperature  | --  | Varies  | This displays °C (°F). This is the current starter/generator control module (SGCM) converter temperature.  | 
SGCM Internal Temperature  | --  | Varies  | This displays °C (°F). This is the current starter/generator control module (SGCM) internal temperature.  | 
SGCM Inverter Temperature  | --  | Varies  | This displays °C (°F). This is the current starter/generator control module (SGCM) inverter temperature.  | 
Starter Generator Speed  | --  | Varies  | This displays RPM.  | 
Starter Generator Temperature  | --  | Varies  | This displays °C (°F).  | 
Output Control  | Description  | 
|---|---|
Brake Hold Sol. 1  | This output control commands the brake hold solenoid 1 ON and OFF.  | 
Brake Hold Sol. 2  | This output control commands the brake hold solenoid 2 ON and OFF.  | 
SGCM Field Current  | This output control commands the starter/generator control module (SGCM) field current ON and OFF.  |