GM Service Manual Online
For 1990-2009 cars only
Makes
🢒
Chevrolet
🢒
2009
🢒
Malibu
🢒
Diagnostic Navigation
🢒
Vehicle Diagnostic Information
🢒 Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Exhaust
Removal Procedure
Remove the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement
.
Disconnect the engine wiring harness electrical connector (5) from the bank 1 exhaust camshaft position (CMP) actuator solenoid valve.
Remove the CMP actuator solenoid valve bolt.
Remove the CMP actuator solenoid valve.
Inspect the CMP actuator solenoid valve seal and replace as necessary.
Installation Procedure
Inspect the CMP actuator solenoid valve seal for damage. Replace the seal if necessary.
Install the CMP actuator solenoid valve.
Caution:
Refer to
Fastener Caution
in the Preface section.
Install the CMP actuator solenoid valve bolt and tighten to
10 N·m (89 lb in)
.
Connect the engine wiring harness electrical connector (5) to the bank 1 exhaust CMP actuator solenoid valve.
Install the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement
.