Exhaust Manifold Heat Shield Replacement LAT
Removal Procedure
- Remove the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement.
- Disconnect the engine wiring harness electrical connector (1) from the heater coolant pump (2).
- Remove the exhaust manifold heat shield bolt (3) securing the heater coolant pump bracket.
- Reposition and secure the heater coolant pump (1) and bracket out of the way.
- Remove the remaining exhaust manifold heat shield bolts (1).
- Remove the exhaust manifold heat shield (2).
Installation Procedure
- Install the exhaust manifold heat shield (2) onto the manifold.
Caution: Refer to Fastener Caution in the Preface section.
- Install the 2 exhaust manifold heat shield bolts (1) and tighten to
23 N·m (17 lb ft).
Note: Ensure that the heater coolant pump bracket tabs (2) are positioned on either side of the heat shield bracket.
- Position the heater coolant pump (1) and bracket to the heat shield bracket.
- Install the remaining exhaust manifold heat shield bolt (3) and tighten to
23 N·m (17 lb ft).
- Connect the engine wiring harness electrical connector (1) to the heater coolant pump (2).
- Install the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement.
Exhaust Manifold Heat Shield Replacement LE5 With MH8
Callout
| Component Name
|
Preliminary proceduresRemove the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement
|
1
| Bolt (Qty 3)
Caution: Refer to Fastener Caution in the Preface section.
Tighten 10 N·m (89 lb in) |
2
| Exhaust Manifold Heat Shield
|