Engine Coolant Thermostat Replacement LZ4

Removal Procedure


    Object Number: 1583645  Size: SH
  1. Drain the cooling system. Refer to Cooling System Draining and Filling .
  2. Remove the air cleaner outlet duct. Refer to Air Cleaner Outlet Resonator Replacement .
  3. Reposition the radiator outlet hose clamp at the thermostat housing.
  4. Remove the radiator outlet hose from the thermostat housing.

  5. Object Number: 1556817  Size: SH
  6. Remove the thermostat housing bolt/stud.
  7. Remove the thermostat housing and gasket.
  8. Remove the thermostat.
  9. Clean the gasket surfaces.

Installation Procedure


    Object Number: 1556817  Size: SH
  1. Install a NEW thermostat.
  2. Position a NEW gasket and the thermostat housing to the engine block.
  3. Notice: Refer to Fastener Notice in the Preface section.

  4. Install the thermostat housing bolt/stud.
  5. Tighten
    Tighten the bolt/stud to 10 N·m (89 lb in).


    Object Number: 1583645  Size: SH
  6. Install the radiator outlet hose to the thermostat housing.
  7. Position the radiator outlet hose clamp at the thermostat housing.
  8. Install the air cleaner outlet duct. Refer to Air Cleaner Outlet Resonator Replacement .
  9. Fill the cooling system. Refer to Cooling System Draining and Filling .
  10. Inspect the system for leaks.

Engine Coolant Thermostat Replacement L61

Removal Procedure


    Object Number: 1713058  Size: SH
  1. Drain the cooling system. Refer to Cooling System Draining and Filling .
  2. Reposition the radiator outlet hose clamp at the surge tank.
  3. Remove the radiator outlet hose from the surge tank.

  4. Object Number: 1712757  Size: SH
  5. Reposition the radiator outlet hose clamp at the thermostat housing.
  6. Remove the radiator outlet hose from the thermostat housing.

  7. Object Number: 1713064  Size: SH
  8. Remove the thermostat housing cover bolts and cover.
  9. Remove the thermostat.
  10. Remove and discard the thermostat housing O-ring seal.

Installation Procedure


    Object Number: 1713064  Size: SH
  1. Install a NEW thermostat housing cover O-ring seal.
  2. Install the thermostat.
  3. Notice: Refer to Fastener Notice in the Preface section.

  4. Install the thermostat housing cover bolts.
  5. Tighten
    Tighten the bolts to 10 N·m (89 lb in).


    Object Number: 1712757  Size: SH
  6. Install the radiator outlet hose to the thermostat housing.
  7. Position the radiator outlet hose clamp at the thermostat housing.

  8. Object Number: 1713058  Size: SH
  9. Install the radiator outlet hose to the surge tank.
  10. Position the radiator outlet hose clamp at the surge tank.
  11. Fill the cooling system. Refer to Cooling System Draining and Filling .