J 39194 Oxygen Sensor Wrench
Notice: The use of excessive force may damage the threads in the exhaust manifold/pipe.
Important: The in-line connector and louvered end must be kept clear of grease, dirt or other contaminants. Avoid using cleaning solvents of any type. DO NOT drop or roughly handle the HO2S.
Important: The HO2S may be difficult to remove when the engine temperature is less than 48°C (120°F)
Notice: The oxygen sensor uses a permanently attached pigtail and connector. Do not remove the pigtail from the oxygen sensor. Damage to or removal of the pigtail connector could affect proper operation of the oxygen sensor.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the nuts to 35 N·m (26 lb ft).
Tighten
Tighten the nuts to 30 N·m (22 lb ft).
Important: A special anti-seize compound is used on the HO2S threads. The compound consists of graphite suspended in fluid and glass beads. The graphite will burn away, but the glass beads will remain, making the sensor easier to remove. New or service sensors will already have the compound applied to the threads. If a sensor is removed from an engine and is to be reinstalled, the threads must have anti-seize compound applied before the reinstallation.
Tighten
Tighten the sensor to 42 N·m (30 lb ft).