Remove the EVAP canister purge solenoid valve bracket bolt.
Remove the EVAP canister purge solenoid valve and bracket.
Insert a small flat-bladed tool between the valve and the bracket in order to release the depress the tab (1) securing the valve to the bracket.
Inspect for carbon release in the EVAP canister purge solenoid valve ports. If there is any loose carbon, replace the EVAP canister and any components necessary to remove the carbon particles.
Install the EVAP canister purge solenoid valve onto the bracket until the tab (1) engages the valve. It may be necessary to bend the tab up slightly in order for the tab to engage the valve.
Position the EVAP canister purge solenoid valve and bracket to the cylinder head.