Diagnostic Fault Information

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

Key In Ignition B+

1

1

--

--

Key In Ignition Signal

1

B2961

B2961

--

1. Chime Malfunction

Circuit/System Description

The instrument panel cluster (IPC) generates the audible warning through an acoustic chime generator in the IPC. The IPC receives audible warning requests via the serial data circuit from the body control module (BCM).

Reference Information

Schematic Reference

Audible Warnings Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Audible Warnings Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Verification

Important: Before performing this diagnostics, make sure no indicators are illuminated after the IPC performs a lamp test. If any indicators are illuminated after the bulb test, perform the indicator diagnostics before this diagnostics.

  1. Ignition ON, headlamp switch OFF, verify the scan tool Headlamp Switch parameter is Inactive.
  2. If not Inactive, refer to Headlamps Malfunction .
  3. Ignition ON, park lamp switch OFF, verify the scan tool Park Lamps Switch parameter is Inactive.
  4. If not Inactive refer to Park Lamps Malfunction .
  5. Ignition ON, doors closed, verify the scan tool All Door Lock Command is On.
  6. If not On, refer to Courtesy Lamps Malfunction .
  7. Verify that the Key In Ignition Status parameter is Key In when the key is in the ignition and Key Out when the key is out of the ignition.
  8. If not the specified value, test or replace the IPC.

Circuit/System Testing

  1. Ignition OFF, disconnect the harness connector at the key in ignition switch.
  2. Ignition ON, verify that a test lamp illuminates between the B+ circuit terminal 2 and ground.
  3. If the test lamp does not illuminate, test the B+ circuit for an open/high resistance. If the circuit tests normal and the ignition switch fuse is open, test the signal circuit terminal 5 for a short to ground.
  4. Verify the BCM scan tool Key In Ignition Cylinder Switch parameter is No.
  5. If not the specified value, test the signal circuit terminal 5 for a short to voltage. If the circuit tests normal, replace the BCM.
  6. Install a 3A fused jumper wire between the signal circuit terminal 5 and the B+ circuit terminal 2. Verify the BCM scan tool Key In Ignition Cylinder Switch parameter is Yes.
  7. If not the specified value, test the signal circuit for an open/high resistance. If the circuit tests normal, replace the BCM.
  8. If all circuits test normal, test or replace the ignition switch.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Ignition and Start Switch Replacement
    •  Control Module References for the BCM replacement, setup and programming