• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Low Speed Cooling Fan Relay Control Circuit for Cool/Fan 1 Relay 28 | P0480 | P0480 | P0480 | -- |
Coil Voltage Supply Circuit for Cool/Fan 1 Relay 28 | P0480 | P0480 | P0480 | -- |
High Speed Cooling Fan Relay Control Circuit for Cool/Fan 2 Relay 30 | P0481 | -- | P0481 | -- |
Coil Voltage Supply Circuit for Cool/Fan SER/PAR Relay 29 | P0481 | P0481 | P0481 | -- |
High Speed Cooling Fan Relay Control Circuit for Cool/Fan SER/PAR Relay 29 | P0481 | -- | P0481 | -- |
Coil Voltage Supply Circuit for Cool/Fan SER/PAR Relay 29 | P0481 | P0481 | P0481 | -- |
The engine control module (ECM) commands the fans ON in high speed or low speed. In low speed, the fans are configured in series. In high speed, the fans are configured in parallel.
In low speed operation, the ECM applies ground to the coil side of the low speed fan relay, which is the cool/fan 1 relay 28. Voltage is applied directly to the left cooling fan through the switch side of the low speed fan relay. The right fan is connected in series to the left fan through the de-energized series/parallel relay, which is cool/fan SER/PAR relay 29, so that both fans operate at low speed.
In high speed operation, the ECM applies a ground to the coil side of the low speed fan relay, the series/parallel relay, and the high speed relay, which is the cool/fan 2 relay 30. Voltage is applied directly to the right cooling fan through the switch side of the high speed fan relay. The left cooling fan obtains voltage through the low speed fan relay and ground through the series/parallel relay.
When the ECM is commanding a fan relay ON, the voltage of the control circuit should be low, near 0 volts. When the ECM is commanding a fan relay OFF, the voltage of the control circuit should be high, near battery voltage.
• | The ignition is ON. |
• | The system voltage is between 9-18 volts. |
• | The relay control circuit is transitioned from OFF to ON, or ON to OFF. |
• | An improper voltage level has been detected on the cooling fan relay control circuit. |
• | The condition must be present for a minimum of 30 seconds. |
DTCs P0480 and P0481 are Type B DTCs.
DTCs P0480 and P0481 are Type B DTCs.
Cooling Fan Description and Operation
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
⇒ | If not the specified value, test the control circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If not the specified value, test the control circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If the fan does not activate, test the fan voltage supply circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the fan. |
⇒ | If the fan does not activate, test the affected relay switch voltage supply circuit for a short to ground or an open/high resistance. If the circuit tests normal and its fuse is open, test all connected components and replace as necessary. |
⇒ | If the test lamp does not illuminate, test the affected relay coil voltage supply circuit for a short to ground or an open/high resistance. If the circuit tests normal and its fuse is open, test all connected components and replace as necessary. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |