- Use a small screwdriver in order to pry open the tab of the electrical connector
assembly (35).
- Remove the electrical connector assembly (35) and the O-ring (36).
- Check to see if the vent is damaged or plugged. If so, use a channel
locks type of pliers and a large screwdriver in order to remove the vent assembly
(37).
- Remove the oil pressure test hole plug (38).