To control emissions of Hydrocarbons (HC), Carbon Monoxide (CO), and Oxides of Nitrogen (NOx), a three-way catalytic converter is used. The catalyst within the converter promotes a chemical reaction which oxidizes the HC and CO present in the exhaust gas, converting them into harmless water vapor and carbon dioxide. The catalyst also reduces NOx, converting it to nitrogen. The PCM has the ability to monitor this process using the HO2S 1 and the HO2S 2 heated oxygen sensors. The HO2S 1 sensor produces an output signal which indicates the amount of oxygen present in the exhaust gas entering the three-way catalytic converter. The HO2S 2 sensor produces an output signal which indicates the oxygen storage capacity of the catalyst; this in turn indicates the catalyst's ability to convert exhaust gases efficiently. If the catalyst is operating efficiently, the HO2S 1 signal will be far more active than that produced by the HO2S 2 sensor. If the PCM detects a level of HO2S 2 activity that indicates the catalyst is no longer operating efficiently, DTC P0420 will be set.
• | No VSS, TP sensor, EVAP system, HO2S, Misfire, IAT sensor, MAP sensor Fuel Trim, Fuel Injector circuit, EGR Pintle, ECT sensor, CKP sensor, or MAF sensor DTC(s) set. |
• | The catalyst is ready for testing based on the following criteria: |
• | Intake air temperature is greater than -18°C (0°F). |
• | Engine Coolant Temperature is greater than 75°C (167°F). |
• | Mass Air Flow is between 7 gm/s and 32 gm/s. |
• | Engine load is less than 63% and steady. |
• | Engine speed is between 1000 RPM and 4000 RPM. |
• | Above conditions for up to 4 minutes. |
• | This ensures that the catalyst is sufficiently warmed up for testing purposes. Once these conditions have been met, the PCM can begin collecting the catalyst diagnostic test samples. |
• | Vehicle speed is between 20 and 75 MPH. |
The PCM determines that the catalyst's oxygen storage capacity is below a threshold considered acceptable.
• | The PCM will illuminate the MIL during the first trip in which the diagnostic test has been run and failed. |
• | The PCM will store conditions which were present when the DTC set as Freeze Frame and Fail Records data. |
• | The PCM will turn the MIL OFF during the third consecutive trip in which the diagnostic has been run and passed. |
• | The history DTC will clear after 40 consecutive warm-up cycles have occurred without a malfunction. |
• | The DTC can be cleared by using the scan tool Clear Info function or by disconnecting the PCM battery feed. |
Check for the following conditions:
• | Poor connection at PCM. Inspect harness connectors for backed out terminals, improper mating, broken locks, improperly formed or damaged terminals, and poor terminal to wire connection. |
• | Damaged harness. Inspect the wiring harness for damage. If the harness appears to be OK, observe the display on the scan tool while moving connectors and wiring harnesses related to the sensor. A change in the display will indicate the location of the fault. |
Reviewing the Fail Records vehicle mileage since the diagnostic test last failed may help determine how often the condition that caused the DTC to be set occurs. This may assist in diagnosing the condition.
• | HO2S 1/ HO2S 2 Activity Test: |
- | Ensure that the engine is fully warmed up. |
- | Using a scan tool, monitor HO2S 1 and HO2S 2 displays in Park while using the scan tool IAC RPM control function to maintain a mass air flow of 10 gm/s. Compare the amount of activity (frequency and amplitude) on HO2S 1 to the activity on HO2S 2 over a 30 second period. |
- | If the amount of activity on HO2S 2 is nearly as great as the activity on HO2S 1, a problem exists; use the DTC P0420 diagnostic chart. If much less activity is noted on HO2S 2, the system is functioning properly. |
The TWC Monitor Test Counter displayed on the scan tool may be used to monitor the progress of the TWC diagnostic. To complete the TWC diagnostic with a good catalyst, the counter must be allowed to increment to 49 samples and roll over to 0 at least twice. A failed catalyst will require three or more 50 sample tests to report a failure.
Number(s) below refer to the step number(s) on the Diagnostic Chart.
• | Allow the engine to warm completely. |
• | With the vehicle in Park, monitor mass air flow on the scan tool and hold part throttle to maintain a reading of over 12 gm/s for at least 2 minutes. This will achieve the warm catalyst requirement for running the test. |
• | Operate the vehicle in second or third gear to remain in the DTC P0420 test conditions described in Conditions for Setting DTC as much as possible. If you must stop the vehicle, maintain the warm catalyst criteria as follows: |
- | Place the vehicle in Park or Neutral. |
- | Hold part throttle to maintain a mass air flow reading of over 10 gm/s for the duration of the stop. |
• | The TWC Monitor Test Counter display on the scan tool may be used to monitor the progress of the TWC diagnostic. To complete the TWC diagnostic, the counter must be allowed to increment to 49 and roll over to 0 twice. |
Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Was the Powertrain On-Board Diagnostic System Check performed? | -- | ||||||||||
2 | Are any other DTC(s) set? | -- | Diagnose other DTC first | |||||||||
3 |
Did your inspection reveal a problem? | -- | ||||||||||
4 |
Did your inspection reveal a problem? | -- | ||||||||||
5 |
Did your inspection reveal a problem? | -- | ||||||||||
6 | Replace the Three-Way catalytic converter. Important: Check for conditions which may cause catalyst damage. Refer to Diagnostic Aids. Is action complete? | -- | -- | |||||||||
Note test result; does scan tool indicate DTC P0420 Test Ran and Passed? | 75°C (167°F) 12-15 gm/s | System OK |
Notice: A misfiring condition may damage the replacement three-way catalytic converter. Check for a misfiring condition. If a misfire is present, repair the misfiring condition before replacing the three-way catalytic converter.