Delphi CS
The following bench check may be used to simulate operation on a vehicle.
Use the bench check to verify operation of a CS generator that has been repaired:
Tools Required
J 41450-B Universal
Electronic CS Generator Tester
Use only a test stand with known calibrated generator speed and ampere
load indicators.
- Mount the generator in a suitable test stand according to the
test stand manufacturer's instructions. The test stand must be capable of
driving the generator at 6500 RPM.
- Assure that the test stand battery is a fully charged, 12 V
automotive battery.
- Turn OFF the internal or external test load, depending on the
type of stand used. Connect across the battery terminals.
- Make sure the internal or external ammeter is connected in series
with the test stand leads. The digital multimeter must be capable of measuring
up to 150 A.
- Connect the positive test stand lead to the generator output BAT
terminal.
- Connect the negative test stand lead to the metal housing of the
generator.
- Perform the J 41450-B
self-test procedure according to the manufacturer's instructions to
verify proper operation of the tester.
- Connect the red alligator clip of the J 41450-B
to the generator output terminal and the black alligator
clip to the metal generator housing. The green POWER lamp on the tester should
light. If the lamp lights, go to next step. If the lamp does not light, recheck
the wiring for the correct connections. The lamp will not light if the polarity
or the tester connections are reversed.
- Connect the matching 4-way connector on the J 41450-B
to the generator. The red DIAGNOSTIC
lamp should light. If the lamp lights, go to the next step. If the lamp does
not light, repair the generator for improper assembly or a faulty regulator.
- With both the red and the green lamps lighted on the J 41450-B
, start the test stand and slowly increase
the speed. The red DIAGNOSTIC lamp on the tester should become dark before
the speed reaches 2500 RPM. Increase the speed to 6500 RPM. The red lamp
on the tester should remain dark. If the lamp on the tester becomes dark
at a lower speed, go to next step. If the red lamp either remains lighted
or lights again at the higher speed, repair the generator for either a no-output
or an uncontrolled voltage condition.
- With the test stand driving the generator at 6500 RPM, turn on
the test load and adjust to the load test value shown in
Generator Usage
. The red lamp on the J 41450-B
should remain dark. If the lamp remains
dark, the generator is GOOD and should be returned to service. If the red
lamp lights with the test load at or below the specified value, repair the
generator for a low output condition. If the load test amperes cannot be
reached and the red lamp does not come on, check the test stand load bank
for a low ampere capacity.
- Turn the test load OFF. Stop the test stand.
- Disconnect the ground load from the generator housing before disconnecting
the test lead from generator output BAT terminal.