Removal Procedure
- Remove the negative battery
cable. Refer to
Battery Negative Cable Disconnection and Connection
in engine electrical.
- Note the position of the hoses for installation.
- Remove the electrical connector and hoses from EVAP canister
purge valve.
- Bend the tab on the EVAP canister purge valve mounting bracket
to release the EVAP canister purge valve.
- Remove the EVAP canister purge valve.
Installation Procedure
- Bend tab on mounting
bracket to retain the EVAP canister purge valve.
- Reinstall the EVAP canister purge valve to purge valve mounting
bracket.
Once installed pull on the solenoid to ensure that the part will be
held in place.
- Connect the electrical connector and hoses to the purge valve.
- Reconnect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection