Blower Motor Resistor Replacement for Chevrolet Monte Carlo 1998
Removal Procedure
- Remove the right side instrument panel insulator. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel, Gauges and Console.
- Disconnect the electrical connector from the blower motor resistor.
- Remove the blower motor
resistor attaching bolts.
- Remove the blower motor resistor.
Installation Procedure
- Install the blower motor
resistor.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the blower
motor resistor attaching bolts.
Tighten
Tighten the blower motor resistor bolts to 10 N·m (89 lb in).
- Connect the electrical connector to the blower motor resistor.
- Install the right side instrument panel insulator. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel, Gauges and Console.