The ignition switch supplies Ignition 1 voltage to the inflatable restraint Sensing and Diagnostic Module (SDM) at terminal 10 using Fuse 21. The ignition switch also supplies Ignition 1 voltage to the AIR BAG warning lamp using Fuse 39. The AIR BAG warning lamp is connected to the INFLATABLE RESTRAINT INDICATOR at terminal 7 of the SDM. When the ignition switch is first turned to RUN, the SDM responds by flashing the AIR BAG warning lamp 7 times.
When measurements are requested in this table, use the J 39200 DMM with the correct terminal adapter from the J 35616 Connector Test Adapter Kit. When an inspection for proper connection is requested, refer to Testing for Electrical Intermittents in Wiring Systems. When a wire, connector or terminal repair is requested, use the J-38125 Terminal Repair Kit and refer to Wiring Repairs in Wiring Systems.
The numbers below refer to the step numbers on the diagnostic table:
This test determines whether the malfunction is in the inflatable restraint Sensing and Diagnostic Module (SDM) circuitry or in the instrument cluster power feed circuitry.
This test determines whether voltage is present in the warning lamp circuit.
This test isolates CKT 358 and checks for a short in CKT 358 to B+.
This test determines if the malfunction is in the instrument cluster connector.
This test determines if the open is due to a bad bulb.
This test isolates an open in the warning lamp circuitry.
This test checks whether power is available to the instrument cluster power feed circuit.
This test checks for a short from the instrument cluster power feed circuit to ground.
This test determines whether the short to ground is due to a short in the wiring or internal to the instrument cluster.
This test determines if the malfunction is in the instrument cluster connector.
This test determines whether the malfunction is due to an open power feed circuit from Fuse 39.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the SIR Diagnostic System Check performed? | -- | ||
Does the BRAKE indicator light? | -- | |||
Is the voltage more than the specified value? | 10.0 V | |||
Is the voltage less than the specified value? | 1.0 V | Go to Integrity Check | ||
5 |
Are the repairs complete? | -- | -- | |
Is the connector damaged or corroded? | -- | |||
7 | Repair the instrument cluster harness connector. Refer to Connector Repairs in Wiring Systems. Are the repairs complete? | -- | -- | |
Is the bulb good? | -- | |||
9 |
Are the repairs complete? | -- | -- | |
Is the resistance within the specified values? | 0-5 ohms | |||
11 |
Are the repairs complete? | -- | -- | |
12 | Service the instrument cluster. Refer to IP Cluster Replacement in Instrument Panel, Gages and Console. Are the repairs complete? | -- | -- | |
Is the fuse good? | -- | |||
Is the fuse good? | -- | |||
Is the fuse good? | -- | |||
16 |
Are the repairs complete? | -- | -- | |
17 |
Are the repairs complete? | -- | -- | |
18 | Install Fuse 39. Are the repairs complete? | -- | -- | |
Is the connector damaged or corroded? | -- | |||
20 | Repair the instrument cluster harness connector. Refer to Connector Repairs in Wiring Systems. Are the repairs complete? | -- | -- | |
Measure the resistance between the instrument cluster harness connector terminal C1 to each terminal of Fuse 39 fuseholder. Is either reading within the specified values? | 0-5 ohms | |||
22 |
Are the repairs complete? | -- | -- | |
23 |
Are the repairs complete? | -- | -- | |
24 | Reconnect all the SIR system components, make sure all the components are properly mounted. Have all the SIR components been reconnected and properly mounted? | -- | -- |